Hog Slat Inc. Newton Grove, NC USA March 2017 11 Air Storm Fans Wiring To access motor turn shutter retainer clips so shutter can be removed. Again, make sure that power is disconnected from system prior to servicing . This Power Unit is supplied prewired for 230 volt operation with the proper rotation direction for correct auger rotation. If 115 volt operation is required please see wiring instruction on Motor Data Label for converting to 115 volt operation. Black wire should connect to L1(M1) and White wire should connect to L2(M2). Green should be connected to Ground ELECTRICAL SHOCK HAZARD! • Motor replacement and the associated wiring changes should only be made by qualified and properly trained individuals. • Failure to follow the above warning can cause improper equipment function, premature failure of equipment or electrical shock, leading to property damage or personal injury. Pre-Operation Assessment Before beginning fan operation, please follow the below checklist to ensure that:  Fan power cord securely connected to a good power supply.  All safety labels are visible to personnel that will work in the area.  Exit wire guard and inlet shutter are in place and secured to the fan housing.  No foreign objects are protruding though the fan housing.