AirStorm - Omni-Drive 57in Fan Brochure

WITH OMNI-EC™ TECHNOLOGY AIRSTORM PRO™ FAN 57” AIRSTORM PRO™ AS-57EBPGA-PRO ™

WITH OMNI-EC™ TECHNOLOGY AIRSTORM PRO™ FAN The AirStorm Pro™ 57” Fan, built with premium components and advanced technology features the innovative Omni-EC™ direct drive motor to deliver powerful airflow, exceptional durability, and precise control for efficient, reliable ventilation performance. ADVANCED MOTOR TECHNOLOGY POWERED BY LEESON MOTORS THE ADVANTAGE OF OMNI-EC™ ECM TECHNOLOGY REDUCE DOWNTIME & MAINTENANCE COSTS Eliminate belts, pulleys, and bearings for less downtime and lower maintenance costs. PRECISION VENTILATION CONTROL Unlike traditional induction motors that slow down under load, our EC motor automatically adjusts torque to maintain a consistent speed across a wide range of settings, giving you superior control over your ventilation system. BUILT-IN PROTECTION Features overload protection safeguarding against overheating for lasting performance. Unlike outdated induction direct drive fans that fail in hot weather, the Omni-EC™ motor will continually monitor speed and motor thermal conditions to ensure reliable airflow when you need it most! NO REMOTE DRIVE The drive is embedded directly in the motor, simplifying installation and reducing potential failure points. ENERGY EFFICIENT PERFORMANCE Advanced, energy-efficient Electronically Commutated motors adjust their speed automatically to match airflow needs. This ensures consistent performance while reducing energy consumption and operating costs. LONG LASTING RELIABILITY Built with premium components for years of dependable performance. PROTECTED INVESTMENT Industry-leading 3-Year Full Replacement Warranty (nonprorated) on Omni-EC™ Motor & Drive Combination. 3 YEAR WARRANTY Suitable for 50 Hz and 60 Hz applications. ACTIVE POWER FACTOR CORRECTION (PFC) Reduces noise and current fluctuations typical of standard VFD/ECM systems, delivering amperage draw comparable to traditional beltdriven motors while enabling smaller electrical circuit requirements.

ENERGY REBATES MAY BE AVAILABLE. For more information, contact: Josh Vails, Georgia Poultry Ventilation Director jlvails@hogslat.com +1 (918) 448-8362 $ ADVANCED MOTOR PROTECTION The EC motor features built-in limits for wattage, amperage, and temperature to prevent damage from overloads, ensuring lasting performance. • Power Limit: The motor adjusts RPM twice per second to stay below 2000W, increasing speed as load allows. • Thermal control: Reduces motor speed when the temperature exceeds the threshold, polling every 5 seconds until optimal levels are restored. • Automatic Restart: Enables the motor to automatically resume operation once power is stabilized, ensuring continuous ventilation without the need for manual reset after voltage fluctuations. AIRSTORM PRO™ KEY PERFORMANCE SPECS • Powerful Airflow: 2.28 HP motor delivers robust performance for optimal ventilation. • Optimized Speed: Adjustable speed range (400-700 RPM) allows you to fine-tune airflow to your specific needs. • Energy Efficient: Operates on standard 208-253V power with a low current draw (8.5 Amps). • Smooth Operation: Soft start and stop features extend motor life and reduce stress on components. • Reliable Shutter Opening: “Break Away” feature ensures shutters open fully every time, guaranteeing consistent airflow.

THE AIRSTORM PRO™ ADVANTAGE FEATURE BENEFIT Integrated Motor & Drive (No External Units) Electronically Commutated Motor (ECM) Soft Start & Overload Protection Self-Adjusting Wattage & Thermal Control Fixed & Variable Speed Options Easy Retrofit Unmatched Warranty (Motor & Drive) Simplified Installation: No external VFDs or complex wiring is needed; saving time and money. Optimal Airflow: Precisely controls torque and speed to deliver optimal airflow tailored to your ventilation needs. Extended Motor Life: Prevents burnout from heat and pressure, maximizing motor lifespan. Continuous Operation: Automatically reduces output to prevent overheating, eliminating costly downtime. Configurable Performance: Supports both fixed-speed and variable (0–10V or 10–0V) inputs to achieve precise CFM and energy efficiency (CFM/watt) targets. Seamless Upgrade: Retrofit Kits are available to upgrade existing AirStorm 57” ventilation fans. Protected Investment: Industry-leading 3-Year Full Replacement Warranty (non-prorated) on Omni-EC™ Motor & Drive Combination. Built to last in demanding environments, the AirStorm Pro™ 57” fan features a corrosion-resistant design. The flush-wall mount includes a durable, gel-coated black fiberglass housing, a black poly discharge cone, and a corrosion-resistant poly butterfly shutter. The X-Brace delivers superior fan rigidity by anchoring to housing corners, while rubber mounts dampen vibration for extended fan life. With stainless steel hardware, this corrosion-resistant support ensures lasting performance. Stainless steel prop designed for peak air delivery at typical operating static pressures, providing high airflow at higher speeds and energy efficiency at lower speeds. Corrosion resistant poly dampers seal tight with magnetic closures and dual springs. An aluminum damper ring maintains maximum stability in any temperature extreme. RIGID X-BRACE SUPPORT STAINLESS STEEL PROP POLY BUTTERFLY SHUTTER SMART FEATURES. REAL BENEFITS.

PERFORMANCE (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 38800 659 229.9 8.30 1895 20.5 0.05 37100 657 229.6 8.69 1983 18.7 0.10 35800 658 229.6 9.08 2072 17.3 0.15 32600 633 229.6 8.57 1955 16.7 0.20 29800 634 229.2 9.09 2071 14.4 0.25 27600 626 229.4 8.96 2044 13.5 0.30 22500 604 229.6 8.38 1913 11.8 Setting #9 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 31800 532 230.5 4.59 1053 30.2 0.05 29800 530 230.5 4.87 1115 26.8 0.10 27900 531 230.0 5.20 1190 23.5 0.15 24600 531 229.7 5.56 1271 19.4 0.20 21700 531 229.7 5.73 1309 16.6 0.25 18300 532 229.6 5.79 1324 13.8 0.30 15000 533 229.6 5.84 1334 11.2 Setting #4 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 38700 665 229.2 8.52 1943 19.9 0.05 37300 662 229.3 8.81 2009 18.6 0.10 35900 662 229.1 9.23 2102 17.1 0.15 32100 627 229.6 8.37 1913 16.8 0.20 29300 627 229.6 8.82 2012 14.6 0.25 27100 627 229.6 9.11 2080 13.0 0.30 24400 627 229.6 9.29 2121 11.5 Setting #8 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 30200 502 230.5 3.90 896 33.7 0.05 28200 501 230.0 4.18 957 29.4 0.10 25200 500 230.0 4.50 1029 24.5 0.15 22200 501 230.0 4.77 1089 20.3 0.20 18800 501 230.0 4.89 1115 16.8 0.25 14600 502 230.0 4.85 1107 13.2 0.30 9200 502 229.6 4.98 1136 8.1 Setting #3 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 37200 633 229.5 7.40 1689 22.0 0.05 35700 633 229.3 7.79 1781 20.0 0.10 34400 632 229.1 8.16 1859 18.5 0.15 32400 632 229.1 8.55 1949 16.6 0.20 29900 632 229.0 8.99 2046 14.6 0.25 27400 632 228.7 9.29 2116 13.0 0.30 21900 603 229.9 8.31 1900 11.5 Setting #7 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 27900 466 230.0 3.22 737 37.8 0.05 25500 465 230.0 3.52 804 31.7 0.10 22300 465 230.0 3.77 860 25.9 0.15 19400 466 230.0 3.96 904 21.4 0.20 15100 466 230.0 3.97 904 16.6 0.25 9100 466 229.6 4.00 913 9.9 Setting #2 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 35800 605 230.7 6.52 1497 23.9 0.05 34200 604 230.8 6.87 1579 21.6 0.10 32600 603 230.5 7.17 1644 19.9 0.15 29700 603 230.9 7.66 1759 16.9 0.20 27300 603 230.5 7.96 1825 15.0 0.25 24800 603 230.7 8.18 1876 13.2 0.30 22000 603 230.5 8.31 1904 11.6 Setting #6 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 26400 437 230.4 2.70 614 43.0 0.05 23400 435 230.1 2.96 676 34.6 0.10 20100 435 230.1 3.18 728 27.7 0.15 16400 436 230.3 3.29 755 21.8 0.20 10700 437 230.4 3.21 737 14.5 0.25 6500 435 230.4 3.44 789 8.3 Setting #1 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 33700 569 231.6 5.48 1264 26.7 0.05 31900 567 231.3 5.79 1333 24.0 0.10 30000 567 230.9 6.14 1412 21.2 0.15 27100 567 230.6 6.55 1502 18.0 0.20 24500 567 230.9 6.78 1558 15.8 0.25 21900 568 230.9 6.94 1593 13.7 0.30 18000 568 230.9 6.90 1589 11.3 Setting #5 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 24000 401 230.9 2.14 491 49.0 0.05 20800 399 230.9 2.37 543 38.3 0.10 17000 399 230.9 2.55 581 29.2 0.15 12300 401 230.9 2.57 588 20.9 0.20 6800 400 230.6 2.69 614 11.1 0.25 4000 400 230.9 2.76 632 6.3 Setting #0 *Data taken from BESS Labs Test 24059

SMART VENTILATION Our EC motors work seamlessly with thermostats and sensors using a 0-10V or 10-0V signal, automatically adjusting fan speed to maintain optimal conditions. For applications requiring fixed speeds, the fan can also be configured for operation at a specific CFM and CFM/watt. • Fail-Safe Mode: With 10-0V control, EC motors default to maximum speed if the control signal is lost, ensuring critical ventilation even in system failure. SPEED & DIRECTION CONTROL The rotary switch (0-9) sets RPM or caps variable speed. DIP switches control the voltage input type, speed control mode, and rotation direction. For poultry complexes that require fixed ventilation settings, the fan can also be configured to operate at a specific, constant CFM and CFM/watt without using the variable speed option. 0 1 2 3 4 5 6 7 8 9 400 RPM 433 RPM 466 RPM 500 RPM 533 RPM 567 RPM 700 RPM 667 RPM 633 RPM 600 RPM For fixed speed operation DIP switch positions should be as follows: Fixed Speed Set Up (On/Off) For variable speed operation DIP switch positions should be as follows: Variable Speed Set Up (0-10/10-0 Voltage Control) DIR_SPEED: Ω, SPEED_SET: Ω, VOLT_SET: Ω START/STOP CONTROL • Uses line voltage cycling through a controller relay • Supports traditional 0-10V or 10-0V control • Note: Requires a minimum off time of 60 seconds Option 1: Line Voltage Cycling Control • Maintains constant power with voltage signal control • Treats 0-0.9V as off (10-10.1 in a 10-0V scale), allowing continuous power • No minimum off time required Option 2: Constant Power Voltage Control 0 20 40 60 80 100 0 1 2 3 4 5 6 7 8 9 10 RPM Signal Voltage RPM curves based on voltage signal 0-10V 10-0V 0 20 40 60 80 100 0 1 2 3 4 5 6 RPM Signal Voltage RPM curves based on voltage sign 0-10V 10-0V RPM curves based on voltage signal RPM % 0-10V: DIR_SPEED Ω,SPEED_SET ≈, VOLT_SET Ω 10-0V: DIR_SPEED Ω,SPEED_SET ≈, VOLT_SET ≈

PRECISE CONTROL OVER FAN SPEED AND AIRFLOW Variable voltage signal to control speed and performance. Signal Voltage Setting 9 Setting 8 Setting 7 Setting 6 Setting 5 Setting 4 Setting 3 Setting 2 Setting 1 Setting 0 -0.05” H20 0-10 10-0 rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm 0-0.9 9.1-10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 9 400 17700 400 17700 400 17700 400 17700 400 17700 400 17700 400 17700 400 17700 400 17700 400 17700 2 8 440 20400 430 20100 430 19800 430 19500 420 19200 420 18900 410 18600 410 18300 400 18000 400 17700 3 7 480 23100 470 22500 460 21900 450 21300 440 20700 430 20100 430 19500 420 18900 410 18300 400 17700 4 6 510 25800 500 24900 490 24000 480 23100 460 22200 450 21300 440 20400 430 19500 410 18600 400 17700 5 5 550 28500 530 27300 520 26100 500 24900 480 23700 470 22500 450 21300 430 20100 420 18900 400 17700 6 4 590 31100 570 29700 550 28100 530 26700 500 25200 480 23700 460 22200 440 20700 420 19200 400 17700 7 3 630 33800 600 32100 570 30200 550 28500 530 26700 500 24900 480 23100 450 21300 420 19500 400 17700 8 2 660 35900 630 34500 600 32300 580 30200 550 28200 520 26000 490 24000 460 21900 430 19800 400 17700 9-10 1-0 660 35900 660 35900 630 34400 600 32000 570 29700 530 27200 500 24900 470 22500 430 20100 400 17700 Signal Voltage Setting 9 Setting 8 Setting 7 Setting 6 Setting 5 Setting 4 Setting 3 Setting 2 Setting 1 Setting 0 -0.10” H20 0-10 10-0 rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm 0-0.9 9.1-10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 9 400 13200 400 13200 400 13200 400 13200 400 13200 400 13200 400 13200 400 13200 400 13200 400 13200 2 8 440 16400 430 16000 430 15700 430 15300 420 15000 420 14600 410 14300 410 13900 400 13600 400 13200 3 7 480 19500 470 18800 460 18100 450 17400 440 16700 430 16000 430 15300 420 14600 410 13900 400 13200 4 6 510 22600 500 21600 490 20500 480 19500 460 18500 450 17400 440 16400 430 15300 410 14300 400 13200 5 5 550 25700 530 24400 520 22900 500 21600 480 20200 470 18800 450 17400 430 16000 420 14600 400 13200 6 4 590 28900 570 27100 550 25400 530 23700 500 21900 480 20200 460 18500 440 16700 420 15000 400 13200 7 3 630 32600 600 29900 570 27800 550 25700 530 23700 500 21600 480 19500 450 17400 420 15300 400 13200 8 2 630 32600 630 32600 600 30200 580 27800 550 25400 520 22900 490 20500 460 18100 430 15700 400 13200 9-10 1-0 630 32600 630 32600 630 32600 600 29900 570 27200 530 24300 500 21600 470 18800 430 16000 400 13200 Signal Voltage Setting 9 Setting 8 Setting 7 Setting 6 Setting 5 Setting 4 Setting 3 Setting 2 Setting 1 Setting 0 -0.15” H20 0-10 10-0 rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm 0-0.9 9.1-10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 9 400 6800 400 6800 400 6800 400 6800 400 6800 400 6800 400 6800 400 6800 400 6800 400 6800 2 8 440 11700 430 10500 430 10500 430 10500 420 9200 420 9200 410 7900 410 7900 400 6800 400 6800 3 7 480 16300 470 15200 460 14000 450 12900 440 11700 430 10500 430 10500 420 9200 410 7900 400 6800 4 6 510 19500 500 18500 490 17400 480 16300 460 14000 450 12900 440 11700 430 10500 410 7900 400 6800 5 5 550 23300 530 21400 520 20500 500 18500 480 16300 470 15200 450 12900 430 10500 420 9200 400 6800 6 4 590 26600 570 25000 550 23300 530 21400 500 18500 480 16300 460 14000 440 11700 420 9200 400 6800 7 3 630 29900 600 27300 570 25000 550 23300 530 21400 500 18500 480 16300 450 12900 420 9200 400 6800 8 2 630 29900 630 29900 600 27300 580 25800 550 23300 520 20500 490 17400 460 14000 430 10500 400 6800 9-10 1-0 630 29900 630 29900 630 29900 600 27300 570 25000 530 21400 500 18500 470 15200 430 10500 400 6800 Signal Voltage Setting 9 Setting 8 Setting 7 Setting 6 Setting 5 Setting 4 Setting 3 Setting 2 Setting 1 Setting 0 -0.20” H20 0-10 10-0 rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm rpm cfm 0-0.9 9.1-10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 9 400 21400 400 21400 400 21400 400 21400 400 21400 400 21400 400 21400 400 21400 400 21400 400 21400 2 8 440 23700 430 23500 430 23200 430 22900 420 22700 420 22400 410 22200 410 21900 400 21600 400 21400 3 7 480 26000 470 25500 460 25000 450 24500 440 24000 430 23400 430 22900 420 22400 410 21900 400 21400 4 6 510 28400 500 27600 490 26800 480 26000 460 25300 450 24500 440 23700 430 22900 410 22200 400 21400 5 5 550 30700 530 29700 520 28600 500 27600 480 26600 470 25500 450 24500 430 23500 420 22400 400 21400 6 4 590 33000 570 31700 550 30400 530 29100 500 27900 480 26500 460 25300 440 24000 420 22700 400 21400 7 3 630 35300 600 33800 570 32200 550 30700 530 29100 500 27600 480 26000 450 24500 420 22900 400 21400 8 2 660 37300 630 35900 600 34000 580 32200 550 30400 520 28600 490 26800 460 25000 430 23200 400 21400 9-10 1-0 660 37300 660 37300 630 35800 600 33800 570 31700 530 29600 500 27600 470 25500 430 23400 400 21400 VOLTAGE PERFORMACE

RkJQdWJsaXNoZXIy MTA3MzU=