PERFORMANCE (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 38800 659 229.9 8.30 1895 20.5 0.05 37100 657 229.6 8.69 1983 18.7 0.10 35800 658 229.6 9.08 2072 17.3 0.15 32600 633 229.6 8.57 1955 16.7 0.20 29800 634 229.2 9.09 2071 14.4 0.25 27600 626 229.4 8.96 2044 13.5 0.30 22500 604 229.6 8.38 1913 11.8 Setting #9 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 31800 532 230.5 4.59 1053 30.2 0.05 29800 530 230.5 4.87 1115 26.8 0.10 27900 531 230.0 5.20 1190 23.5 0.15 24600 531 229.7 5.56 1271 19.4 0.20 21700 531 229.7 5.73 1309 16.6 0.25 18300 532 229.6 5.79 1324 13.8 0.30 15000 533 229.6 5.84 1334 11.2 Setting #4 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 38700 665 229.2 8.52 1943 19.9 0.05 37300 662 229.3 8.81 2009 18.6 0.10 35900 662 229.1 9.23 2102 17.1 0.15 32100 627 229.6 8.37 1913 16.8 0.20 29300 627 229.6 8.82 2012 14.6 0.25 27100 627 229.6 9.11 2080 13.0 0.30 24400 627 229.6 9.29 2121 11.5 Setting #8 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 30200 502 230.5 3.90 896 33.7 0.05 28200 501 230.0 4.18 957 29.4 0.10 25200 500 230.0 4.50 1029 24.5 0.15 22200 501 230.0 4.77 1089 20.3 0.20 18800 501 230.0 4.89 1115 16.8 0.25 14600 502 230.0 4.85 1107 13.2 0.30 9200 502 229.6 4.98 1136 8.1 Setting #3 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 37200 633 229.5 7.40 1689 22.0 0.05 35700 633 229.3 7.79 1781 20.0 0.10 34400 632 229.1 8.16 1859 18.5 0.15 32400 632 229.1 8.55 1949 16.6 0.20 29900 632 229.0 8.99 2046 14.6 0.25 27400 632 228.7 9.29 2116 13.0 0.30 21900 603 229.9 8.31 1900 11.5 Setting #7 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 27900 466 230.0 3.22 737 37.8 0.05 25500 465 230.0 3.52 804 31.7 0.10 22300 465 230.0 3.77 860 25.9 0.15 19400 466 230.0 3.96 904 21.4 0.20 15100 466 230.0 3.97 904 16.6 0.25 9100 466 229.6 4.00 913 9.9 Setting #2 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 35800 605 230.7 6.52 1497 23.9 0.05 34200 604 230.8 6.87 1579 21.6 0.10 32600 603 230.5 7.17 1644 19.9 0.15 29700 603 230.9 7.66 1759 16.9 0.20 27300 603 230.5 7.96 1825 15.0 0.25 24800 603 230.7 8.18 1876 13.2 0.30 22000 603 230.5 8.31 1904 11.6 Setting #6 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 26400 437 230.4 2.70 614 43.0 0.05 23400 435 230.1 2.96 676 34.6 0.10 20100 435 230.1 3.18 728 27.7 0.15 16400 436 230.3 3.29 755 21.8 0.20 10700 437 230.4 3.21 737 14.5 0.25 6500 435 230.4 3.44 789 8.3 Setting #1 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 33700 569 231.6 5.48 1264 26.7 0.05 31900 567 231.3 5.79 1333 24.0 0.10 30000 567 230.9 6.14 1412 21.2 0.15 27100 567 230.6 6.55 1502 18.0 0.20 24500 567 230.9 6.78 1558 15.8 0.25 21900 568 230.9 6.94 1593 13.7 0.30 18000 568 230.9 6.90 1589 11.3 Setting #5 (in.H2O) (cfm) RPM Volts Amps Watts cfm/Watt Static Pressure Airflow 0.00 24000 401 230.9 2.14 491 49.0 0.05 20800 399 230.9 2.37 543 38.3 0.10 17000 399 230.9 2.55 581 29.2 0.15 12300 401 230.9 2.57 588 20.9 0.20 6800 400 230.6 2.69 614 11.1 0.25 4000 400 230.9 2.76 632 6.3 Setting #0 *Data taken from BESS Labs Test 24059
RkJQdWJsaXNoZXIy MTA3MzU=