Hog Slat Inc. Newton Grove, NC USA January 2025 16 Air Storm Fans Dip Switches S1 # Switch Label Description ↑ ↓ 1 VOLT_SET Signal Mode 0-10V 10-0V 2 SPEED_SET Variable Speed or Fixed Speed Fixed Speed Variable Speed 3 DIR_SET Rotation Direction, Intake Side Counter Clockwise Clockwise Note: Counterclockwise is the default rotation for all Omni Drive fans. DIR_SET should not be changed. Input Signal TB1 Used for 0-10V signal input. When in use, SPEED_SET should be set to ↓ position Logic Board Layout Fixed Speed Set Up (On/Off) For fixed speed operation DIP switch positions should be as follows: DIR_SPEED: ↑, SPEED_SET: ↑, VOLT_SET: ↑ Rotary switch position will set fixed speed RPM
RkJQdWJsaXNoZXIy MTA3MzU=