Hog Slat Inc. Newton Grove, NC USA January 2025 15 Air Storm Fans • Make sure there are no unusual noises or vibrations when the motor in running. • Avoid contact with energized circuits or rotating parts. • All aspects of the installation must conform to the applicable requirements of the NEC as well as local codes. • Spinning the shaft will induce potentially damaging current to the drive and connections. • Always disconnect electrical power at the fuse box or circuit breaker panel before handling electrical connections or performing maintenance on this unit. Allow the motor to come to a complete stop and wait ONE (1) MINUTE. This allows the capacitors to discharge any residual voltage. • Double-check to make sure that electrical power is removed and that it cannot be turned on while you are working on the equipment. • A poor electrical connection can overheat and cause terminal and/or terminal board failures. Examine the connection carefully for any signs of physical deterioration or loose fit to the motor terminal block. • If there is evidence of deterioration or loose fit, remove the terminals from the lead wire then connect the lead wires directly to the motor terminal block wiring terminals. • Care must be taken to assure connections are made to the proper terminals and adequate electrical clearances are maintained. ! NOTICE ! • The motor and control are assembled as a set. There are no serviceable components in the motor or control. • To prevent permanent damage to the unit, only apply nameplate voltage. • Do not strike the motor shaft with a hammer or other tool as this may damage bearings.