GrowerSELECT AS-54X Series Airstorm Fiberglass Fan Installation Manual

Hog Slat Inc. Newton Grove, NC USA August 2022 25 Air Storm Fans Performance Hog Slat Inc. takes great pride in supplying our customers with fans that meet or exceed their performance numbers. This is achieved by testing fans from the production line and continually working to maintain consistency in test data. AS-54XEBDLP BESS TEST 17263 Static Pressure (in.H2O) Airflow (cfm) Rpm Volts Amps Watts cfm/Watt 0.00 30900 583 229.3 6.92 1486 20.8 0.05 29400 581 229.3 7.14 1535 19.1 0.10 27600 580 229.6 7.36 1586 17.4 0.15 25600 579 229.4 7.57 1630 15.7 0.20 22800 578 229.5 7.80 1680 13.5 0.25 19100 577 229.4 7.91 1706 11.2 0.30 14500 577 229.2 7.98 1721 8.4 AS-54XEBDLP-HE BESS TEST 17265 Static Pressure (in.H2O) Airflow (cfm) Rpm Volts Amps Watts cfm/Watt 0.00 28500 538 230.6 5.78 1228 23.2 0.05 26700 537 230.6 6.00 1279 20.9 0.10 24400 536 230.5 6.15 1313 18.6 0.15 21700 535 230.3 6.34 1353 16.1 0.20 18700 535 230.1 6.45 1378 13.5 0.25 13900 535 229.6 6.47 1381 10.0 0.30 9600 534 230.7 6.73 1448 6.6