GrowerSELECT - HS597-PROX Proximity Hopper Level Control Installation Manual

Hog Slat Inc. Newton Grove, NC USA July 2019 6 Grow-Flex™ Feed Systems Wiring: The HS597-PROX Hopper Level Switch Control utilizes a current robbing capacitive proximity sensor. It is designed to be used as a control signal for relay input only and cannot be connected to motor loads. It is specifically designed to work with Grower Select HS765 Multi-Hopper Switch Isolator where up to four HS597PROX sensors can be connected to control auger motor loads. The sensor is Normally Closed output. When connected to a HS765, the auger motor will turn on until feed is present in front of the HS597-PROX sensor at which time the auger motor will turn off. The auger motor will turn back on as soon as feed has been removed from the face of the HS597-PROX sensor. The HS597-PROX is rated for 200 mA @ 20-250VAC. Connection to HS765 Multi-Hopper Switch Isolator: