Hog Slat Inc. Newton Grove, NC USA December 2019 3 Cooling System Control Installation: 1. Control Drip System with Timer assembly should be installed in a convenient location near spraying or dripper nozzles. 2. Connect incoming water supply to the 3/4” male adapter and output supply to the 15 PSI pressure reducer. 3. Set 24 hour cycle timer to desired time of day for operation. Refer to instructions on inside of timer cover/lid for adjusting the on/off times of operation and setting actual time of day. 4. Connect power cord to 120V 60 Hz supply. 5. Adjust thermostat for Cooling application: Turn the dial clockwise to a setpoint greater than the space temperature, and the cooling system should cycle off. Turn the dial counterclockwise to a setpoint less than the space temperature, and the cooling system should cycle on. 6. Adjust 30 minute timer for required on/off times. Knobs are adjustable in 1/2 minute increments. (Example - 20 minutes cooling on / 10 minutes cooling off - then cycle repeats)