Hog Slat Inc. Newton Grove, NC USA AUG 2025 REV A5 15 Ventilation System Anytime a selection is made to the left most side Icons to make a change to any of the options, the system will revert back to the MAIN screen even if the unit is in test mode. The “TEST MODE” indicator will be illuminated. At any time you can go back to “TEST MODE” screen by simply pressing the TEST MODE indicator from the MAIN screen. 14D. TEMPERATURE UNITS: Units currently being used is displayed. To change temperature units, press the button icon once to toggle to alternate units. 14E. SELECT MOTOR CURVE STAGE 1: Stage 1 is a variable speed output. Refer to “Motor Curves” section in this manual or motor curve tables under the HELP function (14G) for information regarding motor types, models and curves that best fit. Based on motor being used, select the best motor curve to provide desired motor operation during speed control down to 50% of full speed. 14F. SELECT SEASON: Each operating season Winter, Spring, Summer or Fall can be pre-programmed for set point, curves, alarms etc… Operating season can be recalled at any time or operate the controller with no seasonal selection. Select season, then make changes to features that are impacted by the season of the year. Certain items cannot be changed and are not a part of the season variation. Heat, number of probes and Mist System. Recall any season by pressing icon. If no seasonal changes required simply press the “DE-ACTIVATE” button. This will revert back to single set of data setup. 14G. HELP: Press the HELP button to open a screen with helpful information and description of the screen detail, variables and Motor Curve tables. Indicator of TEST MODE, but also short cut to TEST PANEL SCREEN