Hog Slat Inc. Newton Grove, NC USA AUG 2025 REV A2 23 Ventilation System 19. MIST COOLING: Used to provide additional cooling for animals. Dedicated relay output to control misting unit(s). 19A: MIST ON TIME: Set to the number of minutes for the misting system to be ON. 19B: MIST OFF TIME: Set to the number of minutes for the misting system to be OFF. 19C. MAX HUMIDITY CUT OFF (RH PROBE REQUIRED): This sets the maximum relative humidity level at which time the misting system will turn off regardless if called for by temperature. 19D. OFFSET AND DIFFERENTIAL: The OFFSET + DIFFERENTIAL will set the temperature above the SET-POINT when the mist cooling system will turn ON. The OFFSET sets the temperature above the SET-POINT when the system turns OFF. ================================================================== 20. ALARM: The alarm section has a SPDT relay output function. The Alarm can be used in case of power failure, fault in controller, high/low temperature or probe 1 fault in case only one probe is used. 19A 19B 19C 19D