Hog Slat Inc. Newton Grove, NC USA November 2018 3 Cooling System Control Installation: 1. Control Drip System with Timer assembly should be installed in a convenient location near spraying or dripper nozzles. 2. Connect incoming water supply to the 3/4” male adapter and output supply to the 15 PSI pressure reducer. 3. Connect power cord to 120V 60 Hz supply. 4. Adjust thermostat for Cooling application: Turn the dial clockwise to a setpoint greater than the space temperature, and the cooling system should cycle off. Turn the dial counterclockwise to a setpoint less than the space temperature, and the cooling system should cycle on. 5. Adjust 30 minute timer for required on/off times. Knobs are adjustable in 1/2 minute increments. (Example - 20 minutes cooling on / 10 minutes cooling off - then cycle repeats)