The PolyStorm fan series from Hog Slat.
The PolyStorm fan series from Hog Slat.

It's a whole new take on corrosion-resistant fans. 

Comments (0)
Get your fans ready for summer
Get your fans ready for summer
Basic preseason fan maintenance
Comments (0)
Is changing fan pulleys a cost-effective shortcut to boost fan output?
Is changing fan pulleys a cost-effective shortcut to boost fan output?

Look at all the factors before deciding to replace the pulleys on existing fans to increase wind speed. 

By Tyler Marion, Hog Slat Engineering Group

Comments (0)
Preseason fan maintenance
Preseason fan maintenance

Schedule a preseason tune-up for your fans to maximize their performance this summer. 

Comments (0)
Converting large fans to minimum winter fans
Converting large fans to minimum winter fans

A new control system allows larger fans to be converted to variable speed with improved accuracy and reduced energy consumption.

Most fans used for minimum winter ventilation rates tend to be smaller diameter fans.  It's necessary to use fans with a lower total cubic foot per minute output as the most common method of slowing the fan to reduce air volume is reducing the voltage going to the motor.  It is generally advised not to operate voltage-regulated fans at speeds below 40-50% of their maximum revolutions per minute to prevent the motor from overheating and stalling.

Although smaller fans are effective in delivering the correct minimum rates they do not significantly contribute to the total cfm rate needed to cool the building during maximum ventilation or perform at the highest energy efficiency.

36-fan-&-pit fan

A new method of controlling variable speed fans allows using larger, higher-capacity fans to accurately deliver lower cfm needed for minimum ventilation rates.

Variable Frequency Drive or VFD system uses a three-phase single-speed motor, and VFD controller.  A VFD controller receives a 0 to 10-volt signal from the house controller and sends a corresponding signal to the fan motor in frequency or hertz.  The full range of a VFD fan varies from full delivery down to nearly zero.  This lower cfm range permits a producer to replace several smaller minimum fans on existing facilities with a single, larger VFD fan also functioning as a tunnel fan in the summer. Varying the hertz to control fan speed has a significant advantage over using voltage including less motor overheating and improved energy efficiency because decreasing frequency also reduces power consumption.

VFD-&-Belt Drive

Most fans can be converted to the VFD system by swapping the motor with a three-phase motor and adding a VFD controller. Most whole house computer style controllers are capable of sending a 0 to 10-volt signal to the VFD control.  Older style controllers with on-off signals can also be used with a slightly different method.  The VFD controller features a manual speed control knob.  The operator can set the minimum ventilation, and the ventilation control can override the VFD control and run the fan at high if the building temperature increases.   As the building cools down, the control shuts off and the fan returns to the minimum rate set on the VFD control.

By Austin Baker, Ventilation Director for Hog Slat Inc.  You can contact Austin at jabaker@hogslat.com 

Comments (0)